본문 바로가기 주메뉴 바로가기 하단 바로가기

Active Buzzer

24V ABS Piezo Active Buzzer Alarm With Wire , 95 dB Piezo Transducer
Detailed Product Description
Voltage(VDC):24VDCResonant Frequency:2800±500 Hz
SPL:Min.95dB At 2.8KHz/24VDC 1/2 Duty Square Wave/30cmSize:D42mm*H16mm
Colour:BlackHousing Material:ABS
Buzzer:Piezo BuzzerType:Active

24V ABS Piezo Active Buzzer Alarm With Wire , 95 dB Piezo Transducer

Quick Detail:

  1. Size: D42mm*H16mm
  2. SPL: Min.95dB at 2.8KHz/24VDC 1/2 Duty Square Wave/30cm
  3. Operating Voltage: 8-28VDC
  4. Resonant Frequency: 2800+/-500Hz Continuous

Description:

  1. buzzer
  2. Piezo Buzzer with build-in oscillating
  3. Piezo Buzzer with Wire
  4. 24V Buzzer
  5. 42mm Piezo Buzzer

Specification:

1. Technical Parameter

Measuring condition

Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure.

1

Rated Voltage

24VDC

2

Operating Voltage

8? 28 VDC

3

Rated Current

Max.20mA, at 24VDC

4

Sound Output at 30cm

Min.95dB, at 24VDC

5

Resonant Frequency

2800±500 Hz

6

Tone

Continuous

7

Operating Temperature

-20 - +70℃

8

Storage Temperature

-30 - +80℃

9

RoHS

Yes

10

Weight

Approx 12.0g

2. Dimensions Unit: mm Tolerance: ±0.5mm Except Specified



*Housing Material: Black ABS

3. Reliability Test

After any following tests the part shall meet specifications without any degradation in

appearance and performance except SPL. SPL shall not deviate more than -10 dB

from the initial value

(1)Ordinary Temperature Life Test

The part shall be subjected to 96 hours at 25±10℃. Input rated voltage

Resonant frequency, 1/2 duty Square wave.

(2)High Temperature Test

The part shall be capable of with standing a storage temperature of +80℃ for 96 hours.

(3)Low Temperature Test

The part shall be capable of with standing a storage temperature of ­-30℃ for 96 hours.

(4)Humidity Test

Temperature:+40℃±3℃ Relative Humidity:90%~95% Duration: 48 hours

and expose to room temperature for 6 hours

(5)Temperature Shock Test

Temperature:70℃ /1hour→ 25℃/3hours→-30℃/1hour→ 25℃/3hours (1cycle)

Total cycle: 10 cycles

(6)Drop Test

Standard Packaging From 75mm(Drop on hard wood or board of 5cm thick,

three sides, six plain.)

(7)Vibration Test

Vibration:1000cycles /min. Amplitude:1.5mm, Duration: 1 hour in each 3 axes

Note:

As this product is not protected from foreign material entering, please make sure that any foreign materials (e.g. magnetic powder, washing solvent, flux, corrosive gas) do not enter this product in your production processes. The functional degradation (e.g. SPL down) may occur if foreign material enter it

4.Electrical And Acoustical Measuring Condition

Recommended Setting



Recommended Test Circuit