본문 바로가기 주메뉴 바로가기 하단 바로가기

Magnetic Transducer

6V 16mm Magnetic Transducer With TS16949 Certification for cars
Detailed Product Description

6V 16mm Magnetic Transducer With TS16949 Certification for cars

Quick Detail:

  1. Size: (D)16x (H)14mm
  2. Rated voltage: 6.0Vo-p
  3. Operating voltage: 4 to 8Vo-p
  4. Maximum rated current: 50mA
  5. Minimum sound output: 85dB at 10cm
  6. Coil resistance: 50±7μ
  7. Frequency: 2048Hz
  8. Operating temperatures: -20 to + 70°C
  9. Storage temperatures: -40 to + 85°C
  10. Weight: 5g

Specification:

  1. Technical Parameter

Measuring condition

Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure.

1Rated Voltage6 Vo-p
2Operating Voltage4~8 Vo-p
3Rated CurrentMax.40mA ,at 2048Hz 50% duty Square Wave 6Vo-p
4Sound Output at 10cmMin. 85dB,at 2048Hz 50% duty Square Wave 6Vo-p
5Coil Resistance50±7Ω
6Resonant Frequency2048Hz
7Operating Temperature-20℃~+70℃
8Store Temperature-30℃~+80℃
9Net WeightApprox 4.6g
10RoHSYes

2.Dimensions

Unit: mm


*Unit: mm; Tolerance: ±0.5mm Except Specified

*Housing Material: Black Noryl

3. Electrical And Acoustical Measuring Condition

Recommended Driving Circuit


Resonant frequency, 1/2 duty cycle. Square wave.

Signal amplitude should be large enough tosaturate

the transistor.

Recommended Setting



4. Frequency Response



3Vo-p 50% duty Square wave,10cm