본문 바로가기 주메뉴 바로가기 하단 바로가기

Piezo Alarm Buzzer

Piezo Active Buzzer 12V , Alarm Electronic Buzzers 110db Big Sound Speaker
Detailed Product Description
Size:D40mm*H20mmSPL:Min.110dB, At 12VDC
Voltage(VDC):12VColour:Black
Housing Material:ABS

Piezo Active Buzzer 12V , Alarm Electronic Buzzers 110db Big Sound Speaker

Quick Detail:

  1. Size: D40mm*H20mm
  2. Operating voltage: 3 ? 24 VDC
  3. Rated voltage: 12VDC
  4. Maximum rated current:20mA
  5. Minimum sound output: 110dB at 10cm
  6. Frequency: 2800Hz ± 500Hz
  7. Tone nature: Continuous
  8. Operating temperature: --20?+70℃
  9. Storage Temperature:-30?+80℃
  10. Weight: 12g


Specification:

1.Technical Parameter

Measuring condition

Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H.,

Atmospheric pressure:860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure.

1

Rated Voltage

12 VDC

2

Operating Voltage

3 ? 24 VDC

3

Rated Current

Max.20mA, at 12VDC
Max.50mA, at 24VDC

4

Sound Output at 30cm

Min.110dB, at 12VDC

5

Resonant Frequency

2800±500 Hz

6

Tone

Continuous

7

Operating Temperature

-20 - +70℃

8

Storage Temperature

-30 - +80℃

9

RoHS

Yes

10

Weight

Approx 12g

2. Dimensions Unit: mm Tolerance: ±0.5mm Except Specified

*Housing Material: Black ABS


3. Reliability Test
After any following tests the part shall meet specifications without any degradation in
appearance and performance except SPL. SPL shall not deviate more than -10 dB
from the initial value
(1)Ordinary Temperature Life Test
The part shall be subjected to 96 hours at 25±10℃. Input rated voltage
Resonant frequency, 1/2 duty Square wave.
(2)High Temperature Test
The part shall be capable of with standing a storage temperature of +80℃ for 96 hours.
(3)Low Temperature Test
The part shall be capable of with standing a storage temperature of ­-30℃ for 96 hours.
(4)Humidity Test

Temperature:+40℃±3℃ Relative Humidity:90%~95% Duration: 48 hours
and expose to room temperature for 6 hours
(5)Temperature Shock Test
Temperature:70℃ /1hour→ 25℃/3hours→-30℃/1hour→ 25℃/3hours (1cycle)
Total cycle: 10 cycles
(6)Drop Test
Standard Packaging From 75mm(Drop on hard wood or board of 5cm thick,
three sides, six plain.)
(7)Vibration Test
Vibration:1000cycles /min. Amplitude:1.5mm, Duration: 1 hour in each 3 axes
Note:
As this product is not protected from foreign material entering, please make sure that any foreign materials (e.g. magnetic powder, washing solvent, flux, corrosive gas) do not enter this product in your production processes. The functional degradation (e.g. SPL down) may occur if foreign material enter it

4.Electrical And Acoustical Measuring Condition
Recommended Setting


Recommended Test Circuit


Packing