본문 바로가기 주메뉴 바로가기 하단 바로가기

12V Buzzer

Pin Wireless Electro-Magnetic 12V Buzzer Continuous
Detailed Product Description
Voltage(VDC):12VResonant Frequency:2300±300 Hz
Buzzer:Magnetic BuzzerColour:Black
Housing Material:Black NorylSPL:Min.85dB, At 12VDC

Pin Wireless Electro-Magnetic 12V Buzzer Continuous

Quick Detail:

  1. Size: D16mm*H14mm
  2. Rated Voltage: 12VDC
  3. Operating Voltage: 7-15VDC
  4. Rated Current: Max. 30mA at 12VDC
  5. SPL: Min.85dB at 10cm Input 12VDC
  6. Resonant Frequency: 2300+/-300Hz Continuous


Description:

  1. buzzer
  2. Electro-Magnetic Transduer with build-in oscillating
  3. 12V Buzzer
  4. 16mm Electro-Magnetic Buzzer

Specification:
1.Technical Parameter
Measuring condition
Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure.

1

Rated Voltage

12VDC

2

Operating Voltage

7-15VDC

3

Rated Current

Max.30mA, at 12VDC

4

Sound Output at 10cm

Min.85dB, at 12VDC

5

Resonant Frequency

2300±300 Hz

6

Tone

Continuous

7

Operating Temperature

-20 - +70℃

8

Storage Temperature

-30 - +80℃

9

RoHS

Yes

10

Weight

Approx 2.0 g

2. Dimensions Unit: mm

*Unit: mm; Tolerance: ±0.5mm Except Specified

*Housing Material: Black Noryl


3. Reliability Test
After any following tests the part shall meet specifications without any degradation in
appearance and performance except SPL. SPL shall not deviate more than -10 dB
from the initial value
(1)Ordinary Temperature Life Test
The part shall be subjected to 96 hours at 25±10℃. Input rated voltage
Resonant frequency, 1/2 duty Square wave.
(2)High Temperature Test
The part shall be capable of with standing a storage temperature of +80℃ for 96 hours.
(3)Low Temperature Test
The part shall be capable of with standing a storage temperature of ­-30℃ for 96 hours.
(4)Humidity Test

Temperature:+40℃±3℃ Relative Humidity:90%~95% Duration: 48 hours
and expose to room temperature for 6 hours
(5)Temperature Shock Test
Temperature:70℃ /1hour→ 25℃/3hours→-30℃/1hour→ 25℃/3hours (1cycle)
Total cycle: 10 cycles
(6)Drop Test
Standard Packaging From 75mm(Drop on hard wood or board of 5cm thick,
three sides, six plain.)
(7)Vibration Test
Vibration:1000cycles /min. Amplitude:1.5mm, Duration: 1 hour in each 3 axes
Note:
As this product is not protected from foreign material entering, please make sure that any foreign materials (e.g. magnetic powder, washing solvent, flux, corrosive gas) do not enter this product in your production processes. The functional degradation (e.g. SPL down) may occur if foreign material enter it

4. Electrical And Acoustical Measuring Condition
Recommended Setting


Recommended Test Circuit


Packing